$node = stdClass Object (
[nid] => [16427]
[vid] => [16505]
[type] => [biblio]
[status] => [1]
[created] => [1226181129]
[changed] => [1226183396]
[comment] => [2]
[promote] => [1]
[sticky] => [0]
[revision_timestamp] => [1226183396]
[title] => [Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas.]
[body] => [<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rfr_id=info%3Asid%2Fdiabetescenters.org&rft.genre=article&rft.atitle=Fully+automated+closed-loop+insulin+delivery+versus+semiautomated+hybrid+control+in+pediatric+patients+with+type+1+diabetes+using+an+artificial+pancreas.&rft.title=Diabetes+care&rft.date=2008&rft.volume=31&rft.aulast=Weinzimer+SA&rft.aufirst=Steil+GM+Swan+KL+Dziura+Kurtz+Tamborlane+WV&rft_id=http%3A%2F%2Fcare.diabetesjournals.org%2Fcgi%2Fpmidlookup%3Fview%3Dlong%26pmid%3D18252903"></span><div class="biblio_type"><h3>Publication Type:</h3> Journal Article</div>
<div class="biblio_authors"><h3>Authors:</h3> <a href="/biblio/author/Weinzimer+SA">Weinzimer SA , Steil GM , Swan KL , Dziura J , Kurtz N , Tamborlane WV ,</a></div>
<div class="biblio_source"><h3>Source: </h3> Diabetes care, Volume 31, p.934-9 (2008)</div>
<h3>URL:</h3><a href="http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903">http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903</a>
<h3>Abstract:</h3> <p>OBJECTIVE: The most promising beta-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the beta-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS: We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal "priming" boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 +/- 1.6 years; A1C 7.1 +/- 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS: Mean glucose levels were 135 +/- 45 mg/dl in the HCL group versus 141 +/- 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 +/- 47 mg/dl in the HCL group versus 159 +/- 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 +/- 47 mg/dl in the HCL group versus 226 +/- 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 +/- 27 vs. 112 +/- 28 mg/dl). CONCLUSIONS: Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions. </p>
]
[log] => []
[format] => [1]
[uid] => [1]
[name] => [admin]
[picture] => []
[data] => [a:0:{}]
[biblio_type] => [102]
[biblio_number] => []
[biblio_section] => []
[biblio_other_number] => []
[biblio_secondary_title] => [Diabetes care]
[biblio_tertiary_title] => []
[biblio_short_title] => []
[biblio_alternate_title] => []
[biblio_translated_title] => []
[biblio_authors] => [Weinzimer SA , Steil GM , Swan KL , Dziura J , Kurtz N , Tamborlane WV ,]
[biblio_secondary_authors] => []
[biblio_tertiary_authors] => []
[biblio_corp_author] => []
[biblio_other_author_affiliations] => []
[biblio_edition] => []
[biblio_publisher] => []
[biblio_original_publication] => []
[biblio_reprint_edition] => []
[biblio_place_published] => []
[biblio_year] => [2008]
[biblio_volume] => [31]
[biblio_number_of_volumes] => []
[biblio_pages] => [934-9]
[biblio_date] => []
[biblio_isbn] => []
[biblio_issn] => []
[biblio_lang] => [eng]
[biblio_abst_e] => [<p>OBJECTIVE: The most promising beta-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the beta-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS: We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal "priming" boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 +/- 1.6 years; A1C 7.1 +/- 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS: Mean glucose levels were 135 +/- 45 mg/dl in the HCL group versus 141 +/- 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 +/- 47 mg/dl in the HCL group versus 159 +/- 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 +/- 47 mg/dl in the HCL group versus 226 +/- 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 +/- 27 vs. 112 +/- 28 mg/dl). CONCLUSIONS: Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions. </p>]
[biblio_abst_f] => []
[biblio_full_text] => [0]
[biblio_keywords] => []
[biblio_url] => [http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903]
[biblio_doi] => []
[biblio_issue] => []
[biblio_type_of_work] => []
[biblio_accession_number] => []
[biblio_call_number] => []
[biblio_notes] => []
[biblio_coins] => [<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rfr_id=info%3Asid%2Fdiabetescenters.org&rft.genre=article&rft.atitle=Fully+automated+closed-loop+insulin+delivery+versus+semiautomated+hybrid+control+in+pediatric+patients+with+type+1+diabetes+using+an+artificial+pancreas.&rft.title=Diabetes+care&rft.date=2008&rft.volume=31&rft.aulast=Weinzimer+SA&rft.aufirst=Steil+GM+Swan+KL+Dziura+Kurtz+Tamborlane+WV&rft_id=http%3A%2F%2Fcare.diabetesjournals.org%2Fcgi%2Fpmidlookup%3Fview%3Dlong%26pmid%3D18252903"></span>]
[biblio_research_notes] => []
[biblio_custom1] => [http://www.ncbi.nlm.nih.gov/pubmed/18252903?dopt=Abstract]
[biblio_custom2] => [DK045735]
[biblio_custom3] => [18252903]
[biblio_custom4] => []
[biblio_custom5] => []
[biblio_custom6] => []
[biblio_custom7] => []
[biblio_auth_address] => []
[biblio_remote_db_name] => []
[biblio_remote_db_provider] => []
[biblio_citekey] => [18252903]
[biblio_label] => []
[biblio_access_date] => []
[biblio_type_name] => [Journal Article]
[path] => [biblio/fully-automated-closed-loop-insulin-delivery-versus-semiautomated-hybrid-control-pediatric-pa]
[nodewords] => []
[last_comment_timestamp] => [1226181131]
[last_comment_name] => []
[comment_count] => [0]
[taxonomy] => array (
[89] => stdClass (
[0] => [**Recursion Detected**]
)
)
[files] => []
[page_title] => []
[content] => array (
[body] => array (
[#value] => [<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rfr_id=info%3Asid%2Fdiabetescenters.org&rft.genre=article&rft.atitle=Fully+automated+closed-loop+insulin+delivery+versus+semiautomated+hybrid+control+in+pediatric+patients+with+type+1+diabetes+using+an+artificial+pancreas.&rft.title=Diabetes+care&rft.date=2008&rft.volume=31&rft.aulast=Weinzimer+SA&rft.aufirst=Steil+GM+Swan+KL+Dziura+Kurtz+Tamborlane+WV&rft_id=http%3A%2F%2Fcare.diabetesjournals.org%2Fcgi%2Fpmidlookup%3Fview%3Dlong%26pmid%3D18252903"></span><div class="biblio_type"><h3>Publication Type:</h3> Journal Article</div>
<div class="biblio_authors"><h3>Authors:</h3> <a href="/biblio/author/Weinzimer+SA">Weinzimer SA , Steil GM , Swan KL , Dziura J , Kurtz N , Tamborlane WV ,</a></div>
<div class="biblio_source"><h3>Source: </h3> Diabetes care, Volume 31, p.934-9 (2008)</div>
<h3>URL:</h3><a href="http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903">http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903</a>
<h3>Abstract:</h3> <p>OBJECTIVE: The most promising beta-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the beta-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS: We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal "priming" boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 +/- 1.6 years; A1C 7.1 +/- 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS: Mean glucose levels were 135 +/- 45 mg/dl in the HCL group versus 141 +/- 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 +/- 47 mg/dl in the HCL group versus 159 +/- 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 +/- 47 mg/dl in the HCL group versus 226 +/- 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 +/- 27 vs. 112 +/- 28 mg/dl). CONCLUSIONS: Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions. </p>
]
[#printed] => [1]
)
[#children] => [<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rfr_id=info%3Asid%2Fdiabetescenters.org&rft.genre=article&rft.atitle=Fully+automated+closed-loop+insulin+delivery+versus+semiautomated+hybrid+control+in+pediatric+patients+with+type+1+diabetes+using+an+artificial+pancreas.&rft.title=Diabetes+care&rft.date=2008&rft.volume=31&rft.aulast=Weinzimer+SA&rft.aufirst=Steil+GM+Swan+KL+Dziura+Kurtz+Tamborlane+WV&rft_id=http%3A%2F%2Fcare.diabetesjournals.org%2Fcgi%2Fpmidlookup%3Fview%3Dlong%26pmid%3D18252903"></span><div class="biblio_type"><h3>Publication Type:</h3> Journal Article</div>
<div class="biblio_authors"><h3>Authors:</h3> <a href="/biblio/author/Weinzimer+SA">Weinzimer SA , Steil GM , Swan KL , Dziura J , Kurtz N , Tamborlane WV ,</a></div>
<div class="biblio_source"><h3>Source: </h3> Diabetes care, Volume 31, p.934-9 (2008)</div>
<h3>URL:</h3><a href="http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903">http://care.diabetesjournals.org/cgi/pmidlookup?view=long&pmid=18252903</a>
<h3>Abstract:</h3> <p>OBJECTIVE: The most promising beta-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the beta-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS: We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal "priming" boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 +/- 1.6 years; A1C 7.1 +/- 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS: Mean glucose levels were 135 +/- 45 mg/dl in the HCL group versus 141 +/- 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 +/- 47 mg/dl in the HCL group versus 159 +/- 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 +/- 47 mg/dl in the HCL group versus 226 +/- 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 +/- 27 vs. 112 +/- 28 mg/dl). CONCLUSIONS: Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions. </p>
]
[#printed] => [1]
)
[links] => array (
[comment_forbidden] => array (
[title] => [<a href="/user/login?destination=comment/reply/16427%2523comment-form">Login</a> to post comments]
[html] => [1]
)
)
);